KemiDose | pH · ORP · Chlorine
0000139024 rev. 1.0 EN
6
§ Dosing Type pH: Proportional, OFF, On/OFF
§ Dosing Type ORP: Proportional, OFF, On/OFF
Note: The ORP dosing is disabled if Dosing type chlorine is different than OFF
§ Dosing Type Chlorine: Proportional, OFF, On/OFF
§ Max Flow Rate pumps: 100% (default: 100% [160 strokes/min], range:10-100%)
§ Aux Relay
Aux1 Relay: pH, Disable
Aux2 Relay: Chlorine, ORP, Disable
o Note: Aux1 and Aux2 relays dose with ON/OFF method
§ Password: 0000 (Note: password disabled, set a value other than: 0000)
§ Reset Calibration (Note: select the measure to reset: pH; Chlorine; ORP)
§ Reset All Parameters
§ PROG Control Panel: displays the electrical signals
§ Reed (display error, when red): NO/NC
§ Power ON Delay: Disables the dosing pumps for the set time
§ Flow Delay: Disables the dosing pumps for the set time
Note: Timeout setting menu, after 120 seconds without action the controller escape itself without saving parameters.
View Parameters
Calibration Menu:
Press (3 seconds) and calibrate probe pH, Chlorine, Temperature, ORP
1.4ppm 7.4pH
25°C 720mV
ORP Measure
Alarms:
Lev CL(ORP)
OFA ORP
pH measure
Alarms:
Lev pH
OFA pH
Free Chlorine Measure
Alarms:
Lev CL
OFA CL
Temperature or Totalizer
Flowrate measure,
Moreover,
Alarms sharing messages
Circ. Pump OFF
Flow (Reed OFF)
WiFi OFF
Remote standby deletes
all the measures