OPL BASIC cod. 0000136322
and the buzzer sounds when there is a level alarm status. It is nec
Blinking green fast: the pump is in delay time.
Blinking green slow: the pump is in lock
Red: the pump is running in calibration mode. (See sec
tion 3.1.1 for full description)
Blinking red: the system is in calibration mode. (See section 3.1.1 for full description)
Routine maintenance on the
unit includes preventive maintenance on the squ
eeze tubes and keeping the
unit clean. Repairs to the unit involve modular component replacements. This minimizes spare parts inventory
requirements and speeds up the service process in the field.
Replace squeeze tubes on regular
maintenance intervals. A planned preventive maintenance schedule will insure
replacement before the tube fails. In the event the tube does rupture, clean all product from pump with a damp cloth.
Disconnect power before servicing the unit;
Before removing the old tube, position roller assembly with rollers in a vertical position;
Remove the old tube starting from the left; lift the tube and rotate
the roller assembly clockwise;
Before inserting the new tube, position
roller assembly with rollers in horizontal position;
Insert new tube with flat sides facing towards the front; from the left side rotate
the roller holder clockwise
press the pump tube in place;
Insert the transparent lid.
ssible to connect the system to a level float switch.
Check fuse on the circuit board.
Check input terminals on board for correct input voltage. Refer to the circuit board diagram (picture 2).
Check pump output terminals for loose screws and disconnected wires.
Check for proper voltage across motor windings (or solenoid contacts).
Check for obstruction in pump head (or solenoid).
eck the voltage to the system.
Check the voltage to the system.
Check pump operation for proper speed (or check bowl feeder for obstructions).
Check roller block for binding.
Check for proper input volt
age (24 VDC applied to the pump motor terminals will result in the highest speeds).
Check for lubrication on squeeze tube.