IF Output Specifications
• Center Frequency: 70MHz
• Agility: +/- 20MHz
• IF Step Size: 1Hz
• Power Attenuation: 5 to –20 dBm
• Power Accuracy: 1 dB
• Phase Noise:
@ 100Hz, -71 dBc
@ 1 kHz, -81 dBc
@ 10 kHz, -91 dBc
@ 100 kHz, -101 dBc
@ 1 MHz, -111 dBc
• Impedance: 75 Ω
General Specifications
• Line Power: 100 – 120/200 - 240 VAC, 60/50 Hz, 200 Watts
• Operating Temperature: 0 to 50° C
• Operating Humidity: < 95% non-condensing
• Pollution Degree 2
• Installation Category II
• Weight: 12 lbs
• Dimensions: 19” W x 19” D x 1.75” H (1U rack mount chassis)
Warning: Changes or modifications to this unit not expressly approved by SENCORE
could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. Operation of this equipment in
residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Shielded cables must be used with this unit to ensure compliance with the Class A FCC
limits.