EasyManua.ls Logo

Sensitron SMART3G-D2 - Introduction to SMART3 G Gas Detectors; SMART3 G Gas Detector Description

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
Pag. 11
1. Introduction
1.1 Description
This handbook refers to the SMART3G-D2 and SMART3G-D3 gas detectors. All details repor-
ted in this document are to be fullled along with the instructions given on the SMART3G
user manual.
The SMART3G gas detectors are supplied with a windowed cover and a 4-digit display al-
lowing the real time readout of the concentration being measured. Moreover, the display
allows cheking gas detector calibration and moding the alarm thresholds. 5 LEDs describe
gas detector status and 4 smart LEDs color a ring around the display. The display is equipped
with 3 relays, one always associtated to fault conditions and two to alarm thresholds.
Table 1) Technical characteristics
Power supply 12-24 Vdc
Display 4 digits 7 segment
Indications 5 status LEDs and 4 smart LEDs
Outputs 3 relays, 1 associated to fault and 2 to alarm thresholds
Relays contact ratings 1.0A at 30Vdc
Power consumption 18 mA at 24 Vdc
Dimensions D: 70 mm
Figure 1) SMART3G-D2 (on the left) and SMART3G-D3 (on the right)