6
Appendix
Description of the access points
Manual – ECDriveS
®
49
Process
data word
[PO]
Data
type
Designation Bytewise
notation
[byte.bit]
Wordwise
notation
[word.bit]
Description
6
Word InductControlState
12.0
12.7
6.0
6.15
Upstream Wakeup: Wakeup of the upstream zone when
the material being conveyed is taken over by a system
section that is not controlled with ECDriveS
®
.
Value 0x04: Enabling of upstream zone
Value 0x01: Stop of upstream zone
13.0
13.7
7
Word DischargeControlState
14.0
14.7
7.0
7.15
Downstream Lane Full: Control of the downstream zone
when the material being conveyed is taken over by a
system section that is not controlled with ECDriveS
®
.
Value 0x05: Jam product downstream
Value 0x01: Release product downstream
15.0
15.7
8
Word ClearMotorError
16.0
16.7
8.0
8.15
Error reset
Value 0x01: Reset
Value 0x00: Clear bits
17.0
17.7
9
Word Res.
18.0
18.7
9.0
9.15
19.0
19.7
10
Word Res.
20.0
20.7
10.0
10.15
21.0
21.7
11
Word JamClearUpstream
22.0
22.7
11.0
11.15
Manual clearing of the jam error via PLC
Edge 0-->1: Clearing of the jam error
23.0
23.7
12
Word JamClearDownstream
24.0
24.7
12.0
12.15
Manual clearing of the jam error via PLC
Edge 0-->1: Clearing of the jam error
25.0
25.7
13
Word
GlobalDirectionControlUp-
stream
26.0
26.7
13.0
13.15
Control of the change in the direction of flow and accu-
mulation command for fieldbus controllers in the up-
stream zone.
Low-Byte Values
Value 0x00: Function deactivated
Value 0x01: Accumulate group/individual module
Value 0x0B: Reset to configured direction of flow
Value 0x0A: Invert the direction of flow
27.0
27.7
Number of fieldbus controllers whose settings are set in
LowByte.
HighByte
Example:
Activate accumulation for all fieldbus controllers:
0x0001
Activate accumulation for 3 fieldbus controllers: 0x0301
14
Word
GlobalDirectionControlDown-
stream
28.0
28.7
14.0
14.15
Control of the change in the direction of flow and accu-
mulation command for fieldbus controllers in the down-
stream zone.
Low-Byte Values
Value 0x00: Function deactivated
Value 0x01: Accumulate group/individual module
Value 0x0B: Reset to configured direction of flow
Value 0x0A: Invert the direction of flow
29.0
29.7
Number of fieldbus controllers whose settings are set in
LowByte.
HighByte
Example:
Activate accumulation for all fieldbus controllers:
0x0001
Activate accumulation for 3 fieldbus controllers: 0x0301
25938274/EN – 01/2019