Safety notes
Transport
Manual – ECDriveS
®
8
2.6 Transport
Inspect the shipment for damage as soon as you receive the delivery. Inform the ship-
ping company immediately about any damage. If the product is damaged, it must not
be assembled, installed or started up.
Observe the following notes when transporting the device:
Ensure that the product is not subject to mechanical impact.
Before transportation, cover the connections with the supplied protection caps.
Only place the product on the cooling fins or on the side without connectors during
transportation.
Always use lifting eyes if available.
If necessary, use suitable, sufficiently dimensioned handling equipment.
Observe the information on climatic conditions in chapter "Technical data" of the docu-
mentation.
2.7 Installation/assembly
Ensure that the product is installed and cooled according to the regulations in the doc-
umentation.
Protect the product from strong mechanical strain. The product and its mounting parts
must never protrude into the path of persons or vehicles. Ensure that components are
not deformed and insulation spaces are not changed, particularly during transportation
and handling. Electric components must not be mechanically damaged or destroyed.
Observe the notes in chapter Mechanical installation in the documentation.
2.7.1 Restrictions of use
The following applications are prohibited unless the device is explicitly designed for
such use:
Use in potentially explosive atmospheres
Use in areas exposed to harmful oils, acids, gases, vapors, dust, and radiation
Operation in applications with impermissibly high mechanical vibration and shock
loads in excess of the regulations stipulated in EN61800-5-1
Use at an elevation of more than 4000m above sea level
The product can be used at altitudes above 1000 m above sea level up to 4000 m
above sea level under the following conditions:
The reduction of the nominal output current and/or the line voltage is considered
according to the data in chapter Technical data in the documentation.
Above 2000m above sea level, the air and creeping distances are only sufficient
for overvoltage class II according to EN60664. At altitudes above 2000m above
sea level limiting measures must be taken, which reduce the line side overvoltage
from category III to category II for the entire system.
If a protective electrical separation (in accordance with EN 61800‑5‑1 and
EN 60204‑1) is required, then implement this outside the product at altitudes of
more than 2000m above sea level.