5-2-4. Decimal point and division setting
Max decimal point will be 0.001, and digit can be selected among 1, 2, 5, 10, 20,
50. Digit and decimal point must be fulfilled under the below condition.
(division value / Max capacity value) cannot be over 1/20,000. If this condition is not
fulfilled, err-1 will be displayed and move back to capacity setting mode.
5-2-5. Measuring the DEAD Weight of Weighing Scale
After DIVI is displayed, locate the decimal point with and keys, and set the
division with and keys. Press key to save.
When DEAD displays, Press key, then indicator will calculate dead weight of
scale part automatically (While this process, there should be nothing on the scale part.)