SG-2000 MANUAL 136
The SGC Building, 13737 S.E. 26th St. Bellevue, WA. 98005 USA
©1995, SGC, Inc. TEL: (206) 746-6310 FAX: (206) 746-6384
21.20 SG-2000 Performance Measurements
The following is a diagram of how to set up appropriate test equipment to
ascertain the performance of the SG-2000 transceiver.
It is important that the equipment be set up as noted in the diagram on the
following page and that the technician or engineer performing the measurements
insures that all test equipment is in good working order and has been properly
calibrated prior to performing measures.
The SG-2000 is completely aligned and tested at the SGC factory prior to
shipment. No further adjustment of the radio should be necessary. It is
recommended that the operating frequency of the radio be certified by a
qualified technician on an annual basis in conjunction with a good preventative
maintenance program as noted earlier in this manual.
EQUIPMENT LIST FOR TRANSMITTER TEST:
Instrument Manufacturer Model
Tracking Generator Hewlett Packard HP8443A
Spectrum Analyzer Hewlett Packard HP88538B (RF)
HP88538B (IF)
HP141T (Display)
Audio Generator (2) Hewlett Packard HP204D
Oscilloscope Tektronix 5403
Wattmeter Bird 43
Dummy Load Bird 8327
Attenuator Microlab N/A
RF Voltmeter Hewlett Packard HP410C
Temperature Chamber Assoc. Test Labs RD1300
VOM Simpson 260
DC Power Supply Sorenson SRL60-35
Digital Voltmeter Hewlett Packard 970A
RF probe Hewlett Packard N/A
Frequency counter Hewlett Packard 5381A
Time base standard Hewlett Packard H40-107BR