EasyManua.ls Logo

SGC SG-2000 - Power Requirements; SG-2000 Performance Specifications

SGC SG-2000
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SG-2000 MANUAL 2
The SGC Building, 13737 S.E. 26th St. Bellevue, WA. 98005 USA
©1995, SGC, Inc. TEL: (206) 746-6310 FAX: (206) 746-6384
Alarm generator Programmed for standard ITU and CCIR alarm on
emergency frequency 2182 KHz or can be broadcast on any
frequency. Having to press two push-buttons simul-
taneously to activate transmitter prevents accidental alarm.
Operating
temperature -45° to 85° C
Full specification
temperature -30° to 60° C
Approvals FCC type accepted, parts 80, 87 and 90. DOC and
CEPT(pending). Meets CCIR specification for receiver and
transmitter* (see page 5)
Color Black
Front panel Splash proof, removable and may be mounted remotely
1.2 Transceiver Power Requirements
Nominal 13.6 VDC; 0.8A RX, 16A TX (voice)
Full specification
compliance 11.5 VDC
Full operation 10.5 to 18.0 VDC
Current drain when
radio off:
STBY mode,
Oven on; 430 mA
oven off; 80 mA
1.3 SG-2000 Performance Specifications
RECEIVER SPECIFICATIONS
Sensitivity .5µV produces .5W of audio with 10dB SNR (Signal to
noise ratio may vary from 7 to 16 dB at nominal .5 µV
input)
Selectivity 2.4 KHz at -6 dB; 4 KHz at -60 dB shape factor better
than 2:1)
Intermodulation +86 dB (CCIR specification)
Blocking +100 dB (CCIR specification)
Transmodulation + 95 dB (CCIR specification)
Image and IF
rejection +90 dB
Audio output 4W with less than 10% distortion
Audio distortion Less than 5% at 3W

Table of Contents