Doc# E145701 2 - 8
2: Meter Overview and Specifications
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
2.1.4: Measured Values
The following table lists the measured values available in Real Time, Average,
Maximum, and Minimum.
** The Shark® 100 meter measures harmonics up to the 7th order for Current and
up to the 3rd order for Voltage. The Shark® 50 meter does not provide %THD.
Meter’s Measured Values
Measured
Values
Real Time Average Max Min
Voltage L-N X X X
Voltage L-L X X X
Current per
Phase
XXXX
Current
Neutral
X
Watts XXXX
VAR XXXX
VA XXXX
PF XXXX
+Watt-hr X
-Watt-hr X
Watt-hr Net X
+VAR-hr X
-VAR-hr X
VAR-hr Net X
VA-hr X
Frequency X X X
**%THD X X X
Voltage
Angles
X
Current
Angles
X
% of Load
Bar
X