No Procedure on P.C. side No Procedure on UP-600 side
7 Execute the "POSUTILITUTOOL.EXE" on the P.C.
*Please close all other applications while using this utility.
8 Select the ROM object Files by clicking the "Add Files.." button.
9 Push the "SEND" button.
Program data is sent to the UP-600 automatically.
9
Program data is received from the P.C. automatically.
The UP-600 displays.
10 When data sending is completed,
the initial Window is shown after "Complete" window.
10
The UP-600 displays
"Completed."
11 Turn OFF the power.
12
Select "Normal Mode".
Set the "IPL switch" to "OFF".
(Ref. Hardware manual)
13 Execute the "Service Reset" on UP-600.
IPL from Serial I/O
Connected IRDA 115200
21 22 23 24 25 26 27 28
IPL from Serial I/O
Connected IRDA 115200
21 22 23 24 25 26 27 28
29 2A 2B 2C 2D 2E 2F
Completed.
IPL from Serial I/O
Connected IRDA 115200
30 31 32 33 34 35 36 37
38 39 3A 3B 3C 3D 3E 3F
Completed.