3) -2. 02FD
No Procedure on P.C. side No Procedure on UP-600 side
1 Install the "02FD.EXE" on the P.C.
ALL RAM Data UpLoad : Go to "2"
ALL RAM Data DownLoad : Go to "9"
2 ALL RAM Data UpLoad
Connect the P.C. and the UP-600 (CH2) via RS232. (Fig 1)
2 Enter the SRV mode.
Select " 2 SETTING ".
Select " 14 BACKUP SEND"
3 The UP-600 displays
4 Execute the "02FD.EXE" on the P.C.
*Please close all other applications while using this utility.
5 Set the Communication method by pushing the "Setting" Button.
Push the "OK" Button.
6 Push the "Receive Start" Button.
And Select the Receiving File.
7 Communication starts. 7 Push CA/AT key. The UP-600 displays
8 The UpLoad is completed.
The initial Window is shown.
Push the "Exit" Button.
8 The UpLoad is completed.
The SETTING menu is shown.
9 ALL RAM Data UpLoad
Connect the P.C. and the UP-600 (CH2) via RS232. (Fig 1)
9 Enter the SRV mode.
Select " 2 SETTING".
Select " 15 BACKUP RECEIVE"
10 The UP-600 displays
Push the CA/AT key.
SEND DATA ALL RAM
SPEED PROGRAMMED SPEED
BACKUP SEND
SENDING 00000
BACKUP RECEIVE
SPEED PROGRAMMED SPEED