What to do if my Shimaden Controller is in trouble?
- EEdward DavisSep 9, 2025
Examine, repair or replace the product.
What to do if my Shimaden Controller is in trouble?
Examine, repair or replace the product.
Why does the displayed PV value seem incorrect on my Shimaden Controller?
If the displayed PV value seems incorrect on your Shimaden Controller, there are a couple of potential reasons: * The set measuring range code might differ from that of the input sensor or signal. To resolve this, check and ensure that the set measuring range code is correct for the input signal. * There may be erroneous wiring to the input terminals of the sensor. In this case, correct the wiring to the input terminals.
What to do if a key is unable to be operated on Shimaden Controller?
If you find that a key on your Shimaden Controller is not working, consider these possibilities: 1. The keylock function may be enabled. Try releasing the keylock. 2. The product might be deteriorating. In this case, examine the controller and repair or replace it if necessary. 3. If the communication function is active, the controller might be in communication mode (Com). Change the communication setting to the local mode (Loc).
Why does the display go out on my Shimaden Controller and it does not operate?
If the display on the front panel of your Shimaden Controller goes out and the instrument stops operating, here are a few things to check: * There may be a problem with the power supply or wiring connection. Inspect all power-related components and wiring, and ensure everything is correctly connected. * The product itself might be deteriorating. In this case, examine the controller and consider repairing or replacing it.
How to fix too fast ON-OFF action of control output on Shimaden Controller?
If the ON-OFF action of the control output on your Shimaden Controller is too fast: * It's possible that ON-OFF is set for the proportional (P) element of PID control. Change the OFF setting for P to a two-position type ON-OFF action. * The hysteresis value for the ON-OFF action might be too small. Try increasing the hysteresis value.
Specifies suitable locations and environmental conditions for instrument installation.
Instructions for physically installing the controller onto a panel.
Detailed instructions and precautions for connecting the instrument's terminals.
Illustrates the physical terminal connections for SR91, SR92, and SR93/SR94 models.
Lists terminal numbers and their corresponding functions for different models.
Outlines the initial checks and settings required before operating the controller.
Details the step-by-step process for configuring the controller's parameters.
Explains different types of alarms like deviation and absolute value alarms.
Explains Proportional (P), Integral (I), and Derivative (D) control parameters.
Lists common problems, their causes, and remedies.
Details specific error codes, their causes, and recommended solutions.
| Control Method | PID control |
|---|---|
| Input Type | Thermocouple, RTD, DC Voltage, DC Current |
| Power Supply | 100 to 240 VAC, 50/60 Hz |
| Output Type | Relay |
| Display | Digital LED display |
| Dimensions | 96 x 96 x 100 mm |
| Operating Temperature | 0 to 50°C |
| Accuracy | ±0.3% of full scale |