Notice
Please ensure that this instruction manual is given to the final user of the instrument.
Preface
This instruction manual is meant for those who will be involved in the wiring, installation, operation and routine
maintenance of the SR90 series (SR91, SR92, SR93 and SR94) and describes matters to be attended to in handling
the SR90 series, how to install it, its wiring, its functions and operating procedures.
Keep this manual at the work site while handling the instrument and follow the guidance provided herein.
SR90F-1ME
Aug. 2019
SR90 Series
(SR91, SR92, SR93, SR94)
Digital Controller
Instruction Manual
Please check that the delivered product is the correct item or specification you ordered.
Please do not begin operating this product before you read this instruction manual
thoroughly and understand its contents.

Table of Contents

Questions and Answers

  • K
    Kimberly FreemanAug 20, 2025
    What to do if the Shimaden Controller displays an incorrect PV value?
    • C
      Courtney BarrettAug 20, 2025
      If the displayed PV value seems incorrect, verify that the set measuring range code is correct for the input signal. Also, check the wiring to the input terminals of the sensor and correct if necessary.
  • A
    Alexandra WardAug 22, 2025
    What to do if the Shimaden SR93 front panel display goes out and it stops operating?
    • T
      Teresa WilliamsAug 22, 2025
      If the display on the front panel goes out and the instrument does not operate, inspect the power source and wiring connections, checking the wiring. Additionally, examine the product for deterioration and repair or replace it as needed.
  • K
    Karen MasonAug 25, 2025
    Why is my Shimaden SR93 key unable to be operated?
    • D
      denise74Aug 25, 2025
      If a key is unable to be operated, it may be because the keylock is active, so release the keylock. Another reason could be deterioration of the product, in which case you should examine, repair, or replace the product. If the communication function is added, check if the communication mode (Com) has been set, and if so, change the communication setting to the local mode (Loc).
  • J
    johnsonjohnAug 26, 2025
    What to do if Shimaden SR93 Controller indicates higher limit side scaleover?
    • J
      josehensleyAug 27, 2025
      If the controller indicates a higher limit side scaleover, check the thermocouple input wiring for breaks and replace if necessary. Also, check R.T.D. input A wiring for breaks and replace the R.T.D. if needed. For voltage or current input, verify the transmitting unit of measured values and ensure the set code of the measuring range is correct for the input signal; it may be that the input measured value exceeded higher limit of measuring range by 10%.
  • K
    kathy09Aug 28, 2025
    How to fix too fast ON-OFF action of Shimaden Controller control output?
    • D
      Debra ToddAug 28, 2025
      If the ON-OFF action of the control output is too fast, increase the hysteresis value of the ON-OFF action.
  • M
    mollypadillaAug 30, 2025
    What does it mean if the Shimaden SR93 Controller shows a lower limit side scaleover?
    • R
      Raymond FritzAug 30, 2025
      If the controller shows a lower limit side scaleover, check the wiring for reverse polarity or breaks in the measured value input; it may be that the input measured value fell from lower limit of measuring range by 10%.
  • S
    Stephanie ThomasSep 1, 2025
    What to do if Shimaden SR93 Controller displays higher limit side scaleover of cold junction (CJ)?
    • R
      Roberto CabreraSep 1, 2025
      If the controller displays a higher limit side scaleover of the cold junction (CJ), reduce the ambient temperature to the level provided in the environment conditions for the product, if the ambient temperature of the product has exceeded 80°C. In case ambient temperature has not exceeded 80°C, examine the product.
  • A
    alexishamptonSep 3, 2025
    What to do if Shimaden SR93 displays higher limit side scaleover of cold junction (CJ) of thermocouple input?
    • A
      April WhiteSep 3, 2025
      If the Shimaden Controller displays a higher limit side scaleover of the cold junction (CJ) of thermocouple input, raise the ambient temperature to the level provided in the environment conditions for the product if the ambient temperature of the product has fallen to -20°C or lower. In case ambient temperature has not fallen to í20°C or lower, examine the product.
  • B
    bshawSep 5, 2025
    What to do if there is a break of R.T.D. input wiring in Shimaden SR93?
    • X
      xbrownSep 5, 2025
      Check R.T.D. input terminals A, B and B for breaks. If wiring has no problem, replace R.T.D.
  • J
    Jeremy PittsSep 7, 2025
    What does it mean if Shimaden Controller input value from heater current detector has exceeded 55.0A?
    • W
      Wendy ClementsSep 7, 2025
      If the input value from the heater current detector has exceeded 55.0A, it indicates excess current. Reduce the current. Also, examine the product.

Summary

Safety Rules

Installation and Wiring Procedures

Wiring Guidelines

Detailed instructions and precautions for wiring the controller and its components.

Terminal Layout

Diagrams illustrating terminal connections for SR91, SR92, and SR93/SR94 models.

Terminal Arrangement Table

Table mapping terminal names to their numbers for different SR90 series models.

Before Starting Operation

Steps to follow before initial operation, including wiring checks and settings.

Explanation of Screens and Setting

Procedure of Setting in Screen Group 0

Covers setting target values (SV) and manually controlling output 1 and 2.

AT (Auto Tuning) Function

Explains execution, stopping, and conditions for the auto-tuning process.

Standby Mode (STBY) Operation

Details the standby mode, including its function, event handling, and display.

Event Setting and Set Value Bias

Describes setting event types/values and applying optional set value bias.

Explanation of Screen Group and Setting

Measuring Range Code Setting Screen (1-51)

Selects the input type and corresponding measuring range code.

Explanation of Functions

Events

Explains different types of events like deviation, absolute value, standby, and no-standby alarms.

P.I.D. Control Parameters

Explains the proportional (P), integral (I), and derivative (D) components of PID control.

Lower and Higher Limit Setting Limiters

Details the function and operation of output limiters for control output.

Maintenance and Troubleshooting

Cause of Trouble and Troubleshooting

Provides a table of common problems, their causes, and remedies.

Error Codes, Causes and Remedies

Lists error codes, their causes, and corresponding remedies for troubleshooting.

Specifications

Shimaden SR93 Specifications

General IconGeneral
BrandShimaden
ModelSR93
CategoryController
LanguageEnglish

Related product manuals