Table 41PID Setting Parameter
Parameters Codes Factory Default
Proportion P 5
Integral time I 200
Integral time D 30
Over-temp alarm OTP
15
Control cycle HCLE 15
Blower delay FDLY 180
Temp. unit UNIT
4.1.5 Intermittent Operation Setting
1) Hold Menu for about 2 secs. to set current time and week. Press Up or
Down key to set start/stop function of AUTO timer, the time for RONE
intermittent operation, the OFF time of ROFF intermittent operation, the
ON time of RON intermittent operation.
4.1.6 One-week Timing Setting
1) After current time is set, hold menu for about 5 secs, press Up or
Down key to set OFF1 (Mon. off time), OFF2(Tues. off time), OFF3 (Wed.
off time), OFF4(Thur. off time), OFF 5(Fri. off time), OFF6(Sat. off time),
OFF7(Sun.off time).
2) Hold Menu for about 7S, press Up or Down key to set ON1(Mon. start
time), ON2(Tues. start time), ON3(Wed. start time), NO4(Thur. start time),
ON5(Fri. start time), ON6(Sat. start time), ON7(Sun. start time).
4.1.7 Communication Setting (optional functions)
1) Press both Menu key and Up key for 3 seconds, it displays PRO
(communication protocol) setting.
Notes: Communication protocol is fixed to Modbus RTU
protocol—“RTU.
2) Press Up key to enter ID (communication address) setting;
3) Notes: The communication address of every controller in the same system
must be the only one, no repeat use. In principle: communication address
of hopper 1 is 1, communication address of hopper 1 is 2, and so on.