Minimum Typical Maximum
Vibration resistance
4)
5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance
1))
10 g, 16 ms (IEC 60068-2-27)
1)
maximum permissible conductor resistance must be observed.
1))
The temperature difference between sender and receiver must not exceed 25 K.
2)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25 °C
.
3)
Test conditions per axis: 1 octave/minute, amplitude: 0.35 mm, 20 sweeps.
4)
Test conditions per axis: 1,000 shocks.
12.2 Response time
Table 12: Response time dependent on the protective field height
Protective field height in mm Response time in ms
600 10
900 11
1200 12
1500 13
12.3 Power consumption
Table 13: Power consumption, sender and receiver
Protective field height in mm Typical power consumption for
sender in W
Typical power consumption for
r
eceiver in W
1)
Resolution 30 mm Resolution 30 mm
600 0.91 1.82
900 1.01 2.02
1200 1.10 2.21
1500 1.20 2.40
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
t
able values.
12.4 Length of cable
Table 14: Maximum lengths of cable for wire cross-section 0.34 mm
2
, c
opper wire
Single system
Separate connecting cables for
sender and r
eceiver
r
s
b c
S
r
s
b ≤ 85 m c ≤ 15 m
Connection of sender and receiver
via T-connector on the sender
r
s
a
T
c
S
r
s
a + c ≤ 15 m
12 TECHNICAL DATA
62
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Ex 8017023/14Q6/2020-04-27 | SICK
Subject to change without notice

Table of Contents

Related product manuals