9 Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
www.sick.com/Dx50-2
Please note: This documentation may contain further technical data.
9.1
Performance
Table 17: Technical data for performance
Measuring range
1
2
200 mm ... 10,000 mm, 6% remission
200 mm ... 17,000 mm, 18% remission
200 mm ... 30,000 mm, 90% remission
Resolution 0.1 mm
Repeatability
2
3
4
0.5 mm ... 5 mm
Accuracy
4
5
± 7 mm
Light sender Laser, red
Laser class 2 (EN 60825-1) / 1 (EN 60825-1)
Maximum output 250 mW
Pulse duration 3 ns
Wavelength 658 nm
Pulse rate 1/250 (laser class 2) / 1/666 (laser class 1)
Typical light spot size 10 mm x 10 mm (at 10 m)
Laser operating life (MTTF at +25 °C) 100,000 h
1
With the Slow speed setting
2
See repeatability curves
3
Equivalent to 1 σ
4
6% ... 90% remission
5
Temperature drift typically 0.25 mm/K
Table 18: Output time, response time, and switching frequency as a function of the speed setting
(laser class 2)
Super-fast Fast Medium Slow Super-slow
Output time
1
0.33 ms 1.33 ms 3.33 ms 10 ms 30 ms
Response time
2
0.83 ms 3.33 ms 8.33 ms 25 ms 75 ms
Switching frequency
1
1000 Hz 250 Hz 100 Hz 33 Hz 11 Hz
1
Continuous change of the distance from the object in the measuring range.
2
Lateral entry of the object into the measuring range.
Table 19: Output time, response time, and switching frequency as a function of the speed setting
(laser class 1)
Super-fast Fast Medium Slow Super-slow
Output time
1
0.67 ms 2.67 ms 6.67 ms 20 ms 60 ms
Response time
2
1.67 ms 6.67 ms 16.67 ms 50 ms 150 ms
Switching frequency
1
500 Hz 125 Hz 50 Hz 16.6 Hz 5.5 Hz
1
Continuous change of the distance from the object in the measuring range.
2
Lateral entry of the object into the measuring range.
9 TECHNICAL DATA
76
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK
Subject to change without notice

Table of Contents

Related product manuals