9.2 Interfaces
Table 20: Interfaces
Analog output
1
1 x 4 mA ... 20 mA (≤ 450 Ω) / 1 x 0 V … 10 V
(≥ 50 kΩ) / -
Resolution, analog output 16 bit
Switching output
1
2
3
1 x / 2 x complementary / 2 x push-pull: PNP/NPN
(Qx < 100 mA), IO-Link
Hysteresis 0 mm ... 29,950 mm
Data interface IO-Link
WIFI (only WIFI variants) , app for configuring SOPASair
Function Configuration, diagnostics, Access Point / Client
Data transmis‐
sion rate
≤ 54 Mbit/s
Protocol IEEE 802.11 b/g, encryption: WPA2 / WPA
IO-Link
Function Process data, configuration, diagnostics, data storage
Data transmis‐
sion rate
230.4 kbaud
Protocol V1.1
Multifunctional input (MF)
4
1 x
1
Output Q2, adaptable: 4 mA ... 20 mA / 0 V ... 10 V / switching output / Q1 not / deactivated
2
Output Q short-circuit protected, Voltage drop < 3 V
3
Max. total output current < 200 mA
4
Response time ≤ 60 ms
9.3 Mechanics/electronics
Table 21: Information about mechanics and electronics
Supply voltage V
S
1
2
DC 10 V ... 30 V
Residual ripple
3
≤ 5 Vss
Power consumption
4
5
< 1.7 W
Initialization time ≤ 300 ms
Warm-up time ≤ 15 min
Weight 235 g
Housing material
Housing: zinc die cast
Front screen: acrylic glass (PMMA)
Connection type Male connector, M12, 5-pin
Display 3 x LED, LCD (only display variants)
1
Limit values, reverse-polarity protected; operation in short-circuit protected network: max. 8 A
2
When using IO-Link: V
S
> 18 V; when using the analog output: V
S
> 13 V
3
May not fall below or exceed V
S
tolerances
4
At 0 °C
5
Without load
9.4 Ambient data
Table 22: Ambient data
Protection class
TECHNICAL DATA 9
8017154/1AVV/2021-03-24 | SICK O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
77
Subject to change without notice

Table of Contents