Teach in the length of the reference object
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Q
2
Output
→ Function Q
2
/Q
a
/ to → Teach Q
a
→ Length Ref. Object
→ ESC?
Move the object past the sensor
After reference object → Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Function Q
2
/Q
a
= 4-20 mA or 0-10 V
ModeQ
a
= Shape
Factory setting:
-
Teaching in the reference object shape
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Q
2
Output
→ Function Q
2
/Q
a
/ to → Teach Q
a
→ Length Ref. Object
/ to → Shape of ref. object
→ ...
Move the object past the sensor
After the object is automatically saved
to → RUN mode
Necessary default settings:
User level = Advanced
Function Q
2
/Q
a
= 4-20 mA or 0-10 V
ModeQ
a
= Shape
Length Ref. Object = defined
Factory setting:
-
Manually set the shape trigger threshold for Q
a
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Q
2
Output
→ Function Q
2
/Q
a
/ to → Manual Q
a
→ Length Ref. Object
/ to → Self Trigger
000025 (Note: 0 = flashing 0)
/ , / , / , / ,
/ , / to → desired shape trigger
threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Function Q
2
/Q
a
= 4-20 mA or 0-10 V
ModeQ
a
= Shape
Factory setting:
-
6.4.5 Multifunctional input (“MF Input”)
Description
The multifunctional input (MF, at pin 5) is for
OPERATION 6