Display SOPAS ET / SOPASair IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
→ Shape Ref.
Object
1
Teach shape - - - -
→ Self trigger
1
Shape trigger threshold 111
(0x6F)
- - Shape trigger thresh‐
old
→ Q
1
Tolerance
1
Shape Tolerance Q
1
113
(0x71)
- - Shape tolerance Q
1
→ Q
1
SLWarning
1
SLW switching point
(signal level warning)
93
(0x5D)
1
(0x01)
- SLW1 (signal level
warning 1) = Q
1
threshold
1
Advanced user level
11.4.3 Q
2
Output
Display SOPAS ET / SOPASair IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
Q
2
Output Settings Q
2
(Output Q
2
) 63
(0x3F)
- - Switchpoint 2 settings
Function Q
2
/Q
a
Q
2
/Q
a
output function 121
(0x79)
- - Q
2
Output function
→ 4-20 mA 4 mA ... 20 mA 121
(0x79)
- 1 4 mA ... 20 mA
→ 0-10 V 0 V ... 10 V 121
(0x79)
- 2 0 V ... 10 V
→ Switching Switching 121
(0x79)
- 3 Switching
→ Q
2
=Q
1
not not Q
1
121
(0x79)
- 4 not Q
1
→ Off
1
Off 121
(0x79)
- 0 Off
1
Advanced user level
Mode Q
2
Display SOPAS ET / SOPASair IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
ModeQ
2
Q
2
switching function 63
(0x3F)
2
(0x02)
- Q
2
switching function
→ DtO (1point) DtO mode 63
(0x3F)
2
(0x02)
1 Distance to object
(DtO) – 1point
→ Window Window mode 63
(0x3F)
2
(0x02)
2 Window
→ ObSB (Back‐
ground)
ObSB mode 63
(0x3F)
2
(0x02)
128 Background (ObSB)
→ Shape
1
Shape 63
(0x3F)
2
(0x02)
129 Shape comparison
11 APPENDIX
92
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK
Subject to change without notice