6.4.5.3.1 Operating example via display: Confirm teach
Confirmation of the teach via MF (“Confirm teach”)
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → MF Input
→ MF Function
/ to → Confirm Teach
→ No
/ to → Yes
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
MF Function = Teach
Factory setting:
No
6.4.6 Speed setting (“Speed”)
Description
The DT50-2 Pro distance sensor provides the option of setting various speeds.
The Easy user level has five predefined speed settings: Super fast, Fast, Medium
(factory setting), Slow and Super Slow; the Advanced user level additionally has the
configurable Expert mode.
Table 9: Speed settings for the sensor
Easy user level Super
-fast
- Fast Medi
um
- Slow Super
-slow
- -
Advanced user level 0 1 2 3 4 5 6 7 8
Integration time
1
/ out‐
put time (laser class 2)
[ms]
0.33 0.67 1.33 3.33 6.67 10.0 30.0 74.0 160.0
Integration time
1
/ out‐
put time (laser class 1)
[ms]
0.67 1.33 2.67 6.67 13.33 20.0 60.0 148.0 320.0
Integration depth [meas‐
uring cycles]
1 2 4 10 20 30 90 222 480
Response time
2
/ ana‐
log output (laser class 2)
[ms]
0.83 1.67 3.33 8.33 16.67 25.0 75.0 185.0 400.0
Response time
2
/ ana‐
log output (laser class 1)
[ms]
1.67 3.33 6.67 16.67 33.33 50 150 370 800
Switching frequency
2
switching output (laser
class 2) [Hz]
1000.
0
500.0 250.0 100.0 50.0 33.33 11.11 4.50 2.08
Switching frequency
2
switching output (laser
class 1) [Hz]
500 250 125 50 25 16.67 5.5 2.25 1
1
Continuous change of the distance from the object in the measuring range
2
Lateral entry of the object into the measuring range
The selected speed setting affects the performance of the device. The appendix shows
the “repeatability” and “distance” performance data as a function of the remission
values 6%, 18% and 90% for the five predefined speed settings, see "Diagram repeata‐
bility", page 81.