11.4 Reference tables
The following reference tables indicate how the functions are designated for the differ‐
ent operating options, based on the designation in the display. The menu levels in the
display are visualized in the reference table as follows:
■
Menu level 1: bold font
■
Menu level 2: regular font
■
Menu level 3: arrow in front
11.4.1 RUN mode
Display SOPAS ET / SOPASair IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
Min / xxxx / Max /
NoDist
Distance 109
(0x6D)
1
(0x01)
- Distance
SLxxxx Signal level 109
(0x6D)
2
(0x02)
- Signal Level
SQxxx% - - - - -
+ xxx°C Temperature 153(0
x99)
- - Temperature
SHxxx%
1
Shape level 109
(0x6D)
9
(0x09)
- Shape match
1
Advanced user level and use of the shape comparison
11.4.2 Q
1
Output
Display SOPAS ET / SOPASair IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
Q
1
Output Settings Q
1
(Output Q
1
) 61
(0x3D)
- - Switchpoint 1 settings
ModeQ
1
Q
1
switching function 61
(0x3D)
2
(0x02)
- Q
1
Switching function
→ DtO (1point) DtO mode 61
(0x3D)
2
(0x02)
1 Distance to object
(DtO) – 1point
→ Window Window mode 61
(0x3D)
2
(0x02)
2 Window
→ ObSB (Back‐
ground)
ObSB mode 61
(0x3D)
2
(0x02)
128 Background (ObSB)
→ Shape
1
Shape 61
(0x3D)
2
(0x02)
129 Shape comparison
→ Alarm
1
Alarm 61
(0x3D)
2
(0x02)
130 Alarm
→ SLWarning
1
SLW 61
(0x3D)
2
(0x02)
131 SLW (signal level warn‐
ing)
1
Advanced user level
11 APPENDIX
90
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK
Subject to change without notice