18 GMS815P-PS-2G/-3G · Supplementary Operating Instructions · 8016234 V2.0 · © SICK AG
Installation
Subject to change without notice
3.4 Cable installation (general information)
3.4.1 Using suitable cables
The mains cable must comply with standard IEC 60227 or IEC 60245.
Only use cables approved for use in the potentially explosive atmosphere involved.
Only use cables with suitable outer diameters ( Table 1).
Fit connected cables fixed, i.e. fasten cables along the whole length.
3.4.2 Closing off cable inlets correctly
Seal all cable inlets “vapor-proof” (almost gas-tight) before start-up.
Only open those cable inlets to be used for installing cables. Keep the plugs. Refit the
original plug when a cable inlet must be closed again afterwards.
Table 1 Cable diameters
Device component Cable inlets
Suitable for cables with
outer diameter
Mains switch/mains connection All 7 12 mm
[1]
[1] Further technical requirements on the mains cable p. 34, §6.6.
Interface box
Small version 5 10 mm
Large version 6 12 mm
The cable inlets are sealed when delivered.
The cable inlets are part of the approval.
Do not replace cable inlets with a different type of cable inlet.