3.9 Intrinsically safe signal connections (option)
Only valid for the GMS815P-PS-3G with intrinsically safe signal connections.
3.9.1 Technical layout of the intrinsically safe signal connections
When desired, some of the analog outputs, digital inputs and digital outputs can be real-
ized as intrinsically safe signal connections. Additional modules are fitted for this purpose
(Zener barriers). All intrinsically safe connections can be configured according to customer
requirements.
Terminal assignment Individual information delivered with the device
Technical information on intrinsically safe signal connections Operating Instructions
of the Zener barriers
Fig. 5 Zener barriers for intrinsically safe signal connections
3.9.2
Special technical data for intrinsically safe signal connections
1 2
3
4
5 6
7
8
Signal connection Parameter Specification
Analog outputs
[1]
[1] Observe information on zero potential ( p. 25, §3.9.4)
Maximum voltage on connection terminals: 13 V
Allowable load: 0 200 Ω
Digital inputs
Digital outputs
Maximum voltage on connection terminals: 26.5 V
Internal resistance: 300 Ω