INSTALLATION 4
8024534 / 16UW / 2020-02-26 Operating Instructions | InspectorP Rack Fine Positioning 17
Subject to change without notice
Mounting requirements: reflector as positioning mark
•
Ensure that there are no light sources in the field of view of the device.
•
Ensure that the reflector is not contaminated. A reflection must be ensured.
If necessary, clean the reflector.
•
During rack fine positioning with round reflectors, lights structures are searched
for on darker surfaces. Use a polarizing filter to prevent total reflection of the
illumination. The polarizing filter hides the total reflecting light from the surface.
Do not use the polarizing filter for applications with holes.
You can find the the polarizing filter (part number: 2088229) as an accessory in
the Internet at www.sick.com by entering the part number into the search field.