10.3 Process data profile (Index 120)
Predefined process data profiles can be selected using Index 120. By writing Index
120, the values in Index 67, Subindex 17-20 are automatically set to fill values 0-3 or
bytes 0-15 in the process data with the following contents:
Table 20: Process data profile description Index 120
Profile name Value 0 Value 1 Value 2 Value 3
a-RMS profile a-RMS X-axis a-RMS Y-axis a-RMS Z-axis Temperature
v-RMS profile v-RMS X-axis v-RMS Y-axis v-RMS Z-axis Temperature
X-axis profile a-RMS X-axis v-RMS X-axis Kurtosis X-axis Impulse factor X-
axis
Y-axis profile a-RMS Y-axis v-RMS Y-axis Kurtosis Y-axis Impulse factor Y-
axis
Z-axis profile a-RMS Z-axis v-RMS Z-axis Kurtosis Z-axis Impulse factor Z-
axis
PROCESS DATA STRUCTURE 10
8028041/2022-08-16 | SICK O P E R A T I N G I N S T R U C T I O N S | MPB10
51
Subject to change without notice