7 Operation and parameter settings
Description Value range Factory settings
OU2 PARA
Switching function, switching output 2
(if second switching output is available):
Hysteresis function, normally open: HNO
Hysteresis function, normally closed: HNC
Window function, normally open: FNO
Window function, normally closed: FNC
Diagnostic function: DIA
HNO, HNC, FNO, FNC, DIA HNO
P-N PARA
Switching logic for switching outputs: pnp, npn, or push-pull
(applies for both switching outputs, if second switching output is
available. Q1 is always PNP for the IO-Link option)
PNP, NPN, P/P PNP
OUA PARA
(if analog output is available):
Output signal 4 to 20 mA: I
Inverted output signal 20 to 4 mA: IINV
Output signal: 0 to 10 V: U
Inverted output signal 10 to 0 V: UINV
Automatic detection depending on applied load (non-inverted
output signals): AUTO
I, IINV, U, UINV, AUTO AUTO
UNIT Unit Unit of pressure setting in the display BAR, MPA, KPA, PSI, inHg BAR
0SET YES/NO Zero oset correction, max. 5% –
DISM PARA
Indication of switching points/window limits in display areas C
and E: SPRP
Indication of LOW/HIGH values in display areas C and E: LoHi
SPRP, LoHi SPRP
DISU Value Display update 1/2/5/10 Display updates/second 5/s
DISR YES/NO
Turns display indicator in the relevant display eld upside down
electronically
NO