9 Technical data
Enclosure rating IP 65 and IP 67 according to IEC 60529, when plugged in with a suitable
mating connector
Weight approx. 40 g
Table 9: Mechanics/Electronics
9.2 Ambient data
Ambient temperature 0 °C to +60 °C
Storage temperature –20 °C to +80 °C
Relative humidity < 90%
Impact load Max. 30 g, xyz, according to DIN EN 60068-2-27 (11 ms, mechanical shock)
Vibration load Max. 5 g, xyz, according to IEC 60068-2-6 (10 to 150 Hz, vibration with
resonance)
Table 10: Ambient data