5. Screw the cover back on. Recommended tightening torque for the cover screws:
30 Ncm ± 5 Ncm.
6. Switch on the supply voltage for the device.
Interpretation of the stored parameter set
Once it is switched on, the device automatically detects the presence of a memory card
and, depending on the card’s content, behaves as follows:
If the memory card is empty or if does not contain a parameter set that can be
interpreted by the device: the device saves its currently valid internal parameter
set to the card (provided there is sufficient storage space) and starts with the
internal parameter set.
If the card contains a parameter set that can be interpreted by the device: the
device overwrites the currently valid internal parameter set with this external para‐
meter set.
The goal is for the internal parameter set and the parameter set saved externally to
always be identical.
Removing the memory card from the device:
NOTICE
Risk of damage to the memory card!
b
To safely remove the memory card while the device is in operation:
°
In SOPAS ET, execute the Remove SD card command under Analysis/SD card and
wait for SOPAS ET to provide confirmation.
°
If this command is not accessible, the memory card can also be removed
when there is no power to the device.
PRODUCT DESCRIPTION 3
8024536//2019-08-30 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU61x
21
Subject to change without notice