NOTE
Only use types approved by SICK to ensure reliable function of the memory card. You
can find these as accessories online at:
www.sick.com/RFU61x
The memory card has no write protection that can be activated.
Indication of operational readiness
The “microSD” optical indicator shows the status of the memory card after installation
in the device. It lights up in different colors according to the status, see "Optical status
indicators on the display panel", page 51.
NOTICE
Possible data loss!
When the indicator is green (operational), this does not mean that the device is actually
accessing the memory card for reading or writing.
b
Do not remove the memory card or switch off the supply voltage while the follow‐
ing functions are taking place in the device via the SOPAS ET configuration soft‐
ware:
Saving the parameter values using the “permanent” option
Starting functions that access the memory card (e.g. concurrent logging of
data)
Inserting the memory card in the device:
NOTICE
Risk of damage to the memory card!
b
To safely install the memory card, make sure there is no power to the device
before you insert it.
Ensure the IP67 enclosure rating of the device is maintained see "Conditions for speci‐
fied enclosure rating", page 10.
The card slot on the device is located under the cover foil on the side opposite the elec‐
trical connections.
1
2 3
Figure 5: Slot for MicroSD memory card and “USB” connection
1
2 x screw, M2.5 hexagon socket
2
Slot for microSD memory card
3
“USB” connection (female connector, 5-pin, Micro B type)
1. Switch off the supply voltage to the device.
2. Loosen both screws on the cover.
3. Carefully fold up the cover.
4. Making sure it is in the correct position, insert the memory card into the slot until
it locks into place. When doing so, orient the contacts so that they are facing
towards the device and downwards as per the symbol on the device.