EasyManua.ls Logo

SICK STR1

SICK STR1
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Further topics
"D
evice connection (M12, 5-pin)", page 24
4.4.3.2 Safe series connection with T-connector (without diagnostics)
Important information
DANGER
B
ypassing the protective device
The dangerous state may not be stopped in the event of non-compliance.
If a safe series connection is created with T-connectors, the connecting cable must be
mounted so that individual T-connectors (and therefore a safety switch) cannot be eas‐
ily jumpered.
NOTE
If s
afety switches are connected in series via T-connectors, the application diagnostic
output cannot be evaluated.
NOTE
If the series connection is not made using special T-connectors and end connectors,
ensure that inputs In 1 and In 2 are connected to constant 24 V DC at the first safety
switch of the series connection.
Prerequisites
S
afety switch with male connector, M12, 8-pin
Construction
The safe series connection can be implemented using special T-connectors and an end
connector.
Figure 6: Safe series connection using T-connectors
1
STR1 safety switch
2
M12 connection cable, 8-pin
3
End connector
PROJECT PLANNING 4
8018754/12IU/2020-01-30 | SICK O P E R A T I N G I N S T R U C T I O N S | STR1
17
Subject to change without notice

Table of Contents

Related product manuals