Stand-alone connection
8
2
3
4
5 7
1
6
Figure 26: Device connection (male connector, M12, 8-pin, A-coded)
Table 7: Device connection pin assignment (male connector, M12, 8-pin, A-coded)
Pin Wire color
1)
Designation Description
1 White Out AUX DOOR Door application diagnostic out‐
put (not safe)
2 Brown 24 V DC Voltage supply 24 V DC
3 Green MAG +24 V DC Magnet activation 24 V DC
4 Yellow Out AUX DIA Fault application diagnostic out‐
put (not safe)
5 Gray OSSD 1 Output OSSD 1
6 Pink OSSD 2 Output OSSD 2
7 Blue 0 V Voltage supply 0 V DC
8 Red Out AUX LOCK Locking device application diag‐
nostic output (not safe)
1)
Applies to the extension cables recommended as accessories.
For connection to Flexi Loop
8
2
3
4
5 7
1
6
Figure 27: Device connection (male connector, M12, 8-pin, A-coded)
Table 8: Device connection pin assignment for Flexi Loop variant (M12, 8-pin)
Pin Wire color
1)
Designation Description
1 White Out AUX DOOR Door application diagnostic out‐
put (not safe)
2 Brown 24 V DC Voltage supply 24 V DC
3 Green MAG +24 V DC Magnet activation 24 V DC
4 Yellow N.C. Not assigned
5 Gray OSSD 1 Output OSSD 1
6 Pink OSSD 2 Output OSSD 2
7 Blue 0 V Voltage supply 0 V DC
8 Red N.C. Not assigned
1)
Applies to the extension cables recommended as accessories.