Loading...
Analog Electronic Modules
12-110
Distributed I/O System ET 200S
EWA 4NEB 780 6024-02 07
Analog Value Generation
Measuring principle Integrating (sigma-
delta)
Integration and cycle time/
resolution per channel:
Integration time
parameterizable
Yes
Interference frequency
suppression in Hz
60 50
Integration time in
milliseconds
16.7 20
Basic conversion time
including Integration
time in milliseconds
50 60
Additional conversion
time for wire break
check diagnosis in ms
5 5
Additional conversion
time in ms for line
compensation in
three-conductor
connections
50 60
Cycle time in ms Number of active
channels per
module
conversion time
Resolution (including
overrange)
Pt 100; Ni 100;
Ni120; Pt 200;
Ni 200; Pt 500;
Ni 500; Pt 1000;
Ni 1000; Cu 10 /
15 bits + sign
150 300
600 3000 /
15 bits
PTC
1
/ 1 bit
Suppression of Interference, Limits of Error
Interference voltage sup-
pression for f =
n x (f1"1%), (f1 = interfe-
rence frequency)
Common-mode
interference (U
pp
)
Series-mode
interference
(peak interference
value < rated value of
input range)
Min. 90 dB
Min. 70 dB
Crosstalk between the in-
puts
Min. 50 dB
Operational limit (in the en-
tire temperature range, with
reference to the input
range)
Resistance-type sensor "0.1%
Pt100, Pt200, Pt500,
Pt1000 Standard
"1.0 K
Pt100, Pt200, Pt500,
Pt1000 Climatic
"0.25 K
Ni100, Ni120, Ni200,
Ni500, Ni 1000
Standard and Climatic
"0.4 K
Cu10 "1.5 K
Basic error limit for resi-
stance-type sensors (ope-
rational limit at 25 C with
reference to the input
range)
Resistance-type sensor "0.05%
Pt100, Pt200, Pt500,
Pt1000 Standard
"0.6 K
Pt100, Pt200, Pt500,
Pt1000 Climatic
"0.13 K
Ni100, Ni120, Ni200,
Ni500, Ni 1000
Standard and Climatic
"0.2 K
Cu10 "1.0 K
Temperature error (with re-
ference to the input range)
"0.0009%/K
Linearity error (with refe-
rence to the input range)
"0.01%
Repeatability
(in steady state at 25C
with reference to input
range)
"0.05%