EasyManua.ls Logo

Siemens IM 151-7 User Manual

Siemens IM 151-7
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Preface, Contents
Product Overview
1
Getting Started
2
Addressing
3
ET 200S in the PROFIBUS
Network
4
ET 200S in the MPI Network
5
DP Master Module
6
Commissioning and Diagnostics
7
Functions of the IM 151-7 CPU
8
Cycle and Response Times
9
Technical Specifications
10
Changing over from the
IM 151-7 CPU
(6ES7 151-7Ax00-0AB0) to the
IM 151-7 CPU
(6ES7 151-7AA10-0AB0)
11
Position of the IM 151-7 CPU in
the CPU Range
12
Glossary, Index
Edition 11/2003
A5E00058783-04
ET 200S
IM 151-7 CPU Interface Module
Manual
SIMATIC
This manual has the order number:
6ES7151-1AB00-8BA0
The following supplement is part of this documentation:
No. Designation
Drawing number
Edition
1 Product information A5E00385826-02 11/2005

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens IM 151-7 and is the answer not in the manual?

Siemens IM 151-7 Specifications

General IconGeneral
Product type designationIM 151-7 CPU
Memory (program)64 KB
Memory (data)64 KB
Number of Modules Connectable63
Power Supply24 V DC
SeriesET 200S
Compatible WithET 200S
Digital outputs128
Communication InterfacesPROFIBUS DP
Data Transfer RateUp to 12 Mbps
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity5% to 95% (non-condensing)

Summary

Addressing

3.1 Slot-Oriented Addressing of the I/O Modules

Details the default addressing scheme based on module slot allocation in the IM 151-7 CPU.

3.2 User-oriented addressing of the I/O Modules

Describes how to manually assign addresses to I/O modules independently of slot numbers.

ET 200S in the PROFIBUS Network

4.1 ET 200S in the PROFIBUS network

Describes the structure and basic configuration of a PROFIBUS network with ET 200S nodes.

4.3 PROFIBUS address

Explains how to assign PROFIBUS addresses to nodes for unique identification.

ET 200S in the MPI Network

5.1 ET 200S in the MPI network

Describes the structure and configuration of an MPI network with ET 200S nodes.

5.2 MPI address

Explains how to determine and assign MPI addresses for accessing the IM 151-7 CPU.

DP Master Module

6.1 Mounting the DP master module

Provides step-by-step instructions for physically mounting the DP master module.

6.2 Commissioning the IM 151-7 CPU as a DP master

Details the process of commissioning the IM 151-7 CPU to function as a DP master.

Commissioning and Diagnostics

Configuring the IM 151-7 CPU with STEP 7

Explains how to configure the IM 151-7 CPU for various operating modes using STEP 7.

Resetting the memory of the IM 151-7 CPU

Describes when and how to reset the CPU's memory for troubleshooting or initialization.

Functions of the IM 151-7 CPU

8.1 Data for the PROFIBUS-DP

Covers device master files (DDB) and important features of the IM 151-7 CPU for PROFIBUS-DP.

Cycle and Response Times

Technical Specifications

10.1 Technical specifications of the IM 151-7 CPU

Provides detailed technical specifications including order numbers, features, and general system specs.

Changing IM 151-7 CPU (6ES7 151-7Ax00..) to IM 151-7 CPU (6ES7 151-7AA10-0AB0)

Position of the IM 151-7 CPU in the CPU Range

Related product manuals