Functions of the IM 151-7 CPU
8-44
ET 200S IM 151-7 CPU Interface Module
A5E00058783-04
8.12 Parameters
Parameterizable features
The properties and responses of the IM 151-7 CPU can be parameterized. You
carry out this parameterization on different tabs in STEP 7.
Which parameters can be set for the IM 151-7 CPU?
The following table contains all the parameter blocks for the IM 151-7 CPU. The
parameters are explained in the STEP 7 online help.
Table 8-17 Parameter blocks, settable parameters and their ranges for the IM 151-7 CPU
Parameter
blocks
Settable parameters Range
Startup Startup at preset configuration not equal to
actual configuration
Yes/no
Startup after power on Warm restart
Monitoring time for:
Finished message by means of modules
(100 ms)
Transfer of the parameters to modules
(100 ms)
1 to 650
1 to 10000
Diagnostics/Clock Report cause of STOP Yes/no
Synchronization in PLC
Type
Interval
None/as master
1 s/10 s/1 min/10 min/1 h/12 h/24 h
Synchronization to MPI
Type
Interval
None/as master/as slave
1 s/10 s/1 min/10 min/1 h/12 h/24 h
Correction factor 10000 to +10000
Retentivity Number of memory bytes starting with MB 0 0 to 255
Number of S7 timers starting with T 0 0 to 255
Number of S7 counters starting with C 0 0 to 255
Time-of-day
interrupts
OB 10 activation Yes/no
OB 10 execution None
Once
Every minute
Hourly
Daily
Weekly
Monthly
Last day of the month
Annually
Start date for the OB 10 Year-month-day
Start time for the OB 10 Hours:minutes