Loading...
Reinforced roller bearings
Size Grease stability time for permanent lubrication or relubrication interval
for a regreasing system in operating hours at rated speed
Grease quantity for relu‐
brication in g per bearing
Horizontal type of construction (B) Vertical type of construction (V)
3000
rpm
1500
rpm
≤1000
rpm
3000
rpm
1500
rpm
≤1000
rpm
3000
rpm
≤1500
rpm
180
2800
5600
8000
2000
4000
5600
17 17
200 20 20
225 25 25
250
2000
1400
2800
4000
25 25
280
4000
5600
25 35
315 35 25
355 2800 35 50
The specified relubrication intervals are valid for maximum ambient temperatures of 40 °C.
Reduce the relubrication intervals for a
10°C increase in temperature by a factor of 0.7 of the value listed in the table (max. 20
°C = factor 0.5). Times for operation on 60 Hz systems on request.
9.1.7.3 Regreasing intervals and types of grease for operating rolling-contact bearings
Regreasing intervals
The
regreasing intervals for roller bearings in operating hours and the grease types are stated
on the machine's lubricant plate. Regardless of the actual number of operating hours reached,
the machine must be regreased at least once a year. The lubrication information can be found
on the lubricant plate.
Note
Observe the regreasing intervals for the roller bearings
The regreasing intervals for roller bearings are different from the service/inspection intervals
for the machine. Failure to regrease the roller bearings at the specified intervals can result in
bearing damage.
Maintenance
9.1 Inspection and maintenance
LOHER CHEMSTAR 1PS2
Operating Instructions 08/2016 91