9.2.2 Fixing stator cables at the terminal studs
If the terminal box was removed and must now be re-attached, then you must reconnect the
stator cables in the terminal box. If the terminal studs have been damaged during the work,
proceed as follows:
1. Strip the
insulation from the ends of the stator cable so that the remaining insulation almost
extends up to terminal studs .
2. Attach the end sleeves according to DIN 46228 at the ends of the stator cables.
3. Cut the corrugated tubing to the correct length and place it over the stator cable.
4. Drill out the terminal studs according to DIN 46228 corresponding with the cross-section
of the stator cable.
5. Place the terminal studs on the stator cable and secure these with a stud bolt
according to DIN 916.
6. Solder the terminal studs using soft solder L-Sn 90 .
Stator cable with terminal studs
WARNING
Rotor can fall out
If
the
motor is in a vertical position, the rotor can fall out while work is being performed on the
locating bearing. This can result in death, serious injury or damage.
Support or unload the rotor when carrying out work with the machine in a vertical position.
Maintenance
9.2 Corrective Maintenance
LOHER CHEMSTAR 1PS2
Operating Instructions 08/2016 99