- 3 -
PB200-2
MAINTENANCE
SHUTDOWNS
If out of service more than one week, flush mixing
chamber.
Turn pump off.
Place unit power switch in On position to establish
water flow for five minutes.
If out of service for more than two weeks, flush pump
and mixing chamber.
Connect pump suction to a container of mineral oil
(not water).
Place unit power switch in On position to establish
water flow.
Turn pump on and run for three minutes.
Turn pump off.
Continue water flow for five additional minutes.
Drain water from chamber and piping to prevent
freezing.
MAINTENANCE
1. Clean ancillary water and/or polymer strainers
weekly.
2. Flush system monthly following one week
procedure.
3. Refer to the appendix for specific information on
drawings, part identification, and components.
SPECIAL TOOLS
No special tools needed for operation,
maintenance, and repair of components.
LUBRICATION
No lubrication is required.
PREDICTED LIFE SPAN
There is no predicted life span of wear parts as each
application and operation varies.
OPERATING PROCEDURES
For normal
operation, once settings are adjusted based
on operation parameters, the system can simply be
turned ON or OFF. Special operating instructions for
Seasonal
operation do not apply.
EMERGENCY OPERATING INSTRUCTIONS
Emergency operating instructions do not apply to
Siemens Water Technologies – Stranco Products
equipment. In case of an emergency, TURN OFF
POWER TO STOP RUNNING.
DISASSEMBLY, REPAIR, & REASSEMBLY
This equipment is an open-frame design. It allows for
easy removal of all components. There are no special
procedures for removal of parts. If assistance is
required, contact Siemens Water Technologies –
Stranco Products Technical Service at 800-882-6466.
RECOMMENDED SPARE PARTS
QTY.
PART # DESCRIPTION
1 SP-75HV Pump Liquid End
1 7802910 Chamber Mechanical Seal
1 1450318 Belt, Chamber
1 1414001 Bearing, Chamber Base
1 1410002 Bearing, Chamber Top
1 38593 Pump Head
PUMP REPLACEMENT
QTY.
PART # DESCRIPTION
1 AA761-75PBX Pump
TO ORDER PARTS
You may order parts by calling, faxing or mailing your
order.
Phone 800.882.6466 and ask for PolyBlend Parts.
Hours are 8 a.m. to 5 p.m., Central Time,
Monday - Friday.
Fax Fax number is 815.932.5634.
E-mail stranco.water@siemens.com
Address Siemens Water Technologies
P.O. Box 389
Bradley, IL 60915