RUGGEDCOM RS900
Installation Guide
Chapter 2
Installing the Device
Mounting the Device 7
60079-0 and CSA/UL/IEC/EN 60079-15. The enclosure shall have a minimum service temperature range of -40 to
100 °C (-40 to 212 °F).
• The equipment shall be used in an area of not more than pollution degree 2 as defined in IEC/EN 60664-1.
• The serial DB9 console port shall only be used in the safe area.
• The equipment must be appropriately connected to safety Earth upon installation.
NOTE
For further details of the device's compliance with Class I, Division 2, Zone 2 standards, refer to
Section6.1, “Approvals”.
IMPORTANT!
Do not disconnect or open equipment unless power has been switched off or the area is known to be
non-hazardous.
IMPORTANT!
Débrancher ou ouvrir l'équipment seulement si l'alimnetation a été coupée ou si l'on sait que la zone
ne pose aucun danger.
IMPORTANT!
Substitution of the components may impair suitability for Class I, Division 2.
IMPORTANT!
Le remplacement de composants pourrait compromettre l'admissibilité à la Classe I, Division 2.
Sample Hazardous Location Label
The following is an example of the RUGGEDCOM RS900 hazardous location label:
Figure2:Compliance Label (Example)
Section2.4
Mounting the Device
The RUGGEDCOM RS900 is designed for maximum mounting and display flexibility. It can be equipped with
adapters that allow it to be installed on a 35 mm (1.4 in) DIN rail or affixed to a panel.