Chapter 5
Technical Specifications
RUGGEDCOM RS900
Installation Guide
24 Failsafe Alarm Relay Specifications
Non-Hazardous Environments
Input Voltage
Power Supply Type
Minimum Maximum
Internal
Fuse Rating
c
Isolation
Maximum Power
Consumption
d
88 VDC 300 VDC 3.15 A(T) 4 kVAC 10 W
HI
85 VAC 264 VAC 3.15 A(T) 5.5 kVDC 10 W
24 10 VDC 36 VDC 3.15 A(T) 1.5 kVDC 10 W
48 37 VDC 72 VDC 3.15 A(T) 1.5 kVDC 10 W
c
(T) denotes time-delay fuse.
d
Power consumption may vary based on configuration.
Section5.2
Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage Rated Switching Current Isolation
30 VDC 1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
Non-Hazardous Environments
Maximum Switching Voltage Rated Switching Current Isolation
30 VDC 2 A, 60 W
125 VDC 0.24 A, 30 W
125 VAC 0.5 A, 62.5 W
220 VDC 0.24 A, 60 W
250 VAC 0.25 A, 62.5 W
1500 V
rms
for 1 minute
Section5.3
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM
RS900.
Speed
e
10/100Base-TX
Connector RJ45
Duplex
e
FDX/HDX