Chapter 6
Certification
RUGGEDCOM RS900
Installation Guide
30 CSA/Sira
• UL 60950-1
Information Technology Equipment – Safety Part 1: General Requirements
• CAN/CSA-C22.2 No. 213-M1987
Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations
• CAN/CSA-C22.2 No. 60079-0:11
Explosive Atmospheres – Part 0: Equipment – General Requirements
• CAN/CSA-C22.2 No. 60079-15:12
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Construction, Test and Marking of Type of
Protection "n" Electrical Apparatus
• UL 60079-0, Edition 6.0 (2013)
Explosive Atmospheres – Part 0: Equipment – General Requirements
• UL 60079-15, Edition 4.0 (2013)
Explosive Atmospheres – Part 15: Equipment Protection by Type of Protection "n"
• ANSI/ISA-12.12.01-2013
Non-Incendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazardous
(Classified) Locations
The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S. requirements.
It is specifically approved for use in hazardous locations with the following markings:
• Class I, Division 2, Groups A, B, C, D T4
• Ex nA nC IIC T4 Gc
• Class I, Zone 2, AEx nA nC IIC T4 Gc
Section6.1.2
CSA/Sira
When marked with the following ATEX marking, this device is approved for use in hazardous locations under
certificate Sira 15ATEX4262X.
NOTE
For the maximum ambient temperature, refer to the hazardous location label affixed to the device.
The device also meets the requirements of the following CSA/Sira standards:
• 2014/34/EU
Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation
of the laws of the Member States relating to equipment and protective systems intended for use in potentially
explosive atmospheres (recast) Text with EEA relevance