34 EMC and Environmental Type Tests
Test Description Test Levels Severity Levels
AC Power Ports ± 4 kV 4
Earth
Ground Ports
± 4 kV 4
Signal Ports ± 4 kV Line-to-Ground
± 2 kV
4
DC Power Ports ± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
IEC 61000-4-5 Surge
AC Power Ports ± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports 10 V 3
DC Power Ports 10 V 3
AC Power Ports 10 V 3
IEC 61000-4-6 Induced (Conducted) RFI
Earth
Ground Ports
10 V 3
IEC 61000-4-8 Magnetic Field Enclosure Ports 40 A/m Continuous
1000 A/m for 1 s
IEC 61000-4-11 Voltage Dips and Interrupts AC Power Ports 100% for 5 Periods
100% for 50 Periods
Signal Ports 2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
DC Power Ports 2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
IEC 61000-4-12 Damped Oscillatory
AC Power Ports 2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
Signal Ports 30 V Continuous
300 V for 1 s
4IEC 61000-4-16 Mains Frequency Voltage
DC Power Ports 30 V Continuous
300 V for 1 s
4
IEC 61000-4-17 Ripple on DC Power Supply DC Power Ports 10% 3
IEC 61000-4-29 Voltage Dips and Interrupts DC Power Ports 30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
Signal Ports 2 kV (Failsafe Relay Output)
DC Power Ports 1.5 kV
Dielectric Strength
AC Power Ports 2 kV
Signal Ports 5 kV (Failsafe Relay Output)
DC Power Ports 5 kV
IEC 60255-5
HV Impulse
AC Power Ports 5 kV