Upkeep and maintenance
5.1 Downloading new firmware using TFTP without WBM and CLI
SCALANCE XP-200
68 Operating Instructions, 05/2016, C79000-G8976-C428-01
7. Open a Windows command prompt and change to the directory where the file with the
new firmware is located and then execute the following command :
tftp -i <IP address> put <firmware file>
Note
You can enable TFTP in Microsoft Windows as follows:
"Control Panel" > "Programs and Features" > "Turn Windows features on or off" > "TFTP
Client".
8. Once the firmware has been transferred completely to the device and validated, there is
an automatic restart on the device. This may take several minutes.