Connecting up
4.6 Serial interface
SCALANCE XP-200
62 Operating Instructions, 05/2016, C79000-G8976-C428-01
Serial interface
Information on the serial interface
● To connect the serial interface, the device has an M12 interface: A-coded, 5-pin, female.
● Via the serial interface, you can access the CLI of the device directly via an RS-232
connection (115200 8N1) without assigning an IP address.
● Access to the device is also possible independent of the Ethernet ports.
● To connect the serial interface to the PC, you require a cable with an M12 plug and 9-pin
D-sub female connector. You can order the connecting cable for the serial interface as an
accessory.
● When it ships, the cover for the serial interface is secured to the housing see "Device
views (Page 24)".