5 Testing the VRRP scenario
VRRP
Entry-ID: 109798556, V1.0, 09/2021
53
© Siemens AG
2021 All rights reserved
5.3 Error profiles
Error in the configuration of the advertisement interval
Most of the time, these errors occur when the master router and backup router
do not have the same configuration. An example of this is when the
advertisement intervals are set to different values. If the routers receive
different advertisement intervals, then the packets will be discarded until the
problem is resolved.
Errors with the VRRP priority
If the master and backup routers initialize in the wrong order, then check the
VRRP priorities.
Both routers are in the master role
If both routers display that they are the master, then this is a serious problem
and probably indicates an error in the communication path between the
routers. You can check the communication path between the routers by
exchanging a ping command via the router's WBM.
Ping between PC and server fails
The ping to the server fails. Check the wiring of the VLAN configuration and the
IP address configuration. Also make sure that the PC is using the right
gateway address.

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals