Device Properties Article number
SCALANCE XR526-8 24VAC/DC version
24 x 10 / 100 / 1000Mbps RJ45 ports
2 x 1 / 2.5 / 5 / 10 Gbps RJ45 ports
8 x SFP / SFP+ plug-in transceiver slots with 1 / 10 Gbps
2 x 2-pin terminal block 24 V DC / 24 V AC, power supply connection
1 x CLP slot
1 x USB Type B, serial interface connection
1 x 2-pin terminal block 24VDC, signaling contact connection
6GK5534-2TR00-2AR3
100 to 240VAC / 110 to 250VDC version
24 x 10 / 100 / 1000Mbps RJ45 ports
2 x 1 / 2.5 / 5 / 10 Gbps RJ45 ports
8 x SFP / SFP+ plug-in transceiver slots with 1G / 10 Gbps
1 x IEC plug (C14) 100 to 240 V AC, power supply connection, non-
redundant
1 x DC terminal block, 2-pin, 110 to 250VDC, power supply con‐
nection, non-redundant
1 x CLP slot
1 x USB Type B, serial interface connection
1 x 2-pin terminal block 24VDC, signaling contact connection
6GK5534-2TR00-3AR3
100 to 240VAC / 110 to 250VDC version
24 x 10 / 100 / 1000Mbps RJ45 ports
2 x 1 / 2.5 / 5 / 10 Gbps RJ45 ports
8 x SFP / SFP+ plug-in transceiver slots with 1 / 10 Gbps
2 x IEC plug (C14) 100 to 240VAC, power supply connection,
redundant
2 x DC terminal block, 2-pin, 110 to 250VDC, power supply con‐
nection, redundant
1 x CLP slot
1 x USB Type B, serial interface connection
1 x 2-pin terminal block 24VDC, signaling contact connection
6GK5534-2TR00-4AR3
Factory settings: Industrial Ethernet pro󹪝le
Industrial Ethernet protocol: PROFINET
Base Bridge Mode: 802.1Q VLAN Bridge
Redundancy mechanism: RSTP
Trust mode: Trust CoS-DSCP
IGMP Snooping/IGMP Querier: O󹪜
IPv4 Address Collision Detection: Never give up
Description of the device