If you connect a communications node to an unmonitored port or disconnect it, this does not
cause an error message.
The signaling contact remains open until one of the following events occurs:
The problem is eliminated.
The current status is entered in the fault mask as the new desired status.
6.8 USB console interface
Information on the USB console interface
Via the USB console interface on the device (USB socket Type B), you can access the device
directly via a virtual serial interface (115200 8N1) without assigning an IP address.
Access to the device is possible independent of the Ethernet ports.
To connect the USB console interface to a PC, you require a cable with a USB Type B plug and
USB Type A plug. The connecting cable for the USB console interface can be ordered as
accessory; see section "Accessories (Page36)".
Driver for the USB console interface
To use the USB console interface under Windows, you must download and install the following
driver: Drivers (https://support.industry.siemens.com/cs/ww/en/ps/6GK5998-3GS00-2AC2/dl).
Position
The interface is located on the front of the device.
&2162/(
Figure6-8 Position of the USB console interface using a 24VAC/DC device version with 12 SFP/SFP+
slots as an example
Connecting up
6.8USB console interface
SCALANCE XR-500
Operating Instructions, 07/2023, C79000-G8976-C692-01 83