EasyManua.ls Logo

Siemens SCALANCE XR-500 - XR502-32 Ambient Temperature Limits

Siemens SCALANCE XR-500
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical speci󹪝cations
Ambient temperature
2)
Property Startup at -40°C
With LAN operation with RJ45
plug
Up to 2000 m above sea level
During operation in horizontal installation posi‐
tion:
-40°C to +55°C
When operating with plug-in
transceivers of the types:
[-] Standard version
LD except SFP993-1LD
SFP993-1LD up to max. 4
units
Up to 2000 m above sea level
During operation in horizontal installation posi‐
tion:
-40°C to +55°C
When operating with plug-in
transceivers of the types
3)
:
SFP992-1+
LD+
LH (except SFP993-1LH)
LH+
ELH
ELH200
BXMR
BXMT
BX10T
BX10R
Up to 2000 m above sea level
During operation in horizontal installation posi‐
tion:
-40°C to +50°C
When operating with plug-in
transceiver SFP993-1LH
3)
Up to 2000 m above sea level
During operation in horizontal installation posi‐
tion:
-40°C to +40°C
With operation between
2000m and 3000m above
sea level
The maximum ambient temperature is reduced
by 5°C
4)
With operation between
3000m and 4000m above
sea level
The maximum ambient temperature is reduced
by 10°C
4)
During storage -40°C to +85°C
During transportation -40°C to +85°C
Relative humidity During operation at 25 ℃ ≤ 95% without condensation
Housing, dimensions and weight
Design Rack
Housing material Metal
Degree of protection IP20
5) 6)
Dimensions (W x H x D) 446 x 43.5 x 374.8mm (1 height unit)
Weight 8000 g
Technical speci󹪝cations
9.1SCALANCE XR502-32
SCALANCE XR-500
Operating Instructions, 07/2023, C79000-G8976-C692-01 93