Technical speci󹪝cations
Slots for plug-in transceiver
(SFP+)
Quantity 8
Connector SFP/ SFP+ plug-in transceiver
Transmission speed 1 / 10 Gbps
Diagnostics interface
Serial interface Quantity 1
Connector USB Type B
Signaling contact
1)
Quantity 1
Design Spring-loaded terminal block, 2-pin
Permitted voltage range 24VDC
Load rating Max. 100 mA
Button Quantity 1
Con󹪝guration interface
Removable data storage medium Quantity 1
Product name Siemens Con󹪝guration and License PLUG (CLP)
Connection to power supply
Power supply
1)
Design Spring-loaded terminal block, 2-pin
Rated voltage 24VAC / 24VDC
Voltage range 19.2 to 30.0VAC
19.2 to 31.2VDC
Frequency 50 / 60Hz (with AC)
Frequency range 50Hz to 60Hz
Fusing 10 A / 250V
Properties Implemented redundantly;
The connected power supply must meet the require‐
ments of NEC Class 2 or PS2/LPS in compliance with
UL 62368-1.
Degree of pollution 2
Current consumption Rated voltage 3A
E󹪜ective power loss Rated voltage 72W
Cable cross-section Minimum 0.75 mm^2 (AWG 18)
Maximum 2.5 mm^2 (AWG 12)
Permitted ambient conditions
Technical speci󹪝cations
9.2SCALANCE XR522-12
SCALANCE XR-500
98 Operating Instructions, 07/2023, C79000-G8976-C692-01

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals