Safety notes
2.1 Security recommendations
SCALANCE XR-500
Operating Instructions, 05/2017, A5E03275845-11
15
Protocol
Port number
Port status
Default status of the
port
Authentication
Encryption
SNMP
UDP/161 Open (when config-
ured)
Open Yes Yes (when
configured)
SNTP
NTP
UDP/123 Open (when config-
ured)
Closed No No
PROFINET
UDP/34964,
UDP/49154,
49155
Open Open No No
EtherNet/IP
TCP/44818,
UDP/2222,44
818
Open (when config-
ured)
Open No No
DHCP
UDP/67,68 Open (when config-
ured)
Closed No No
Syslog
UDP/514 Open (when config-
ured)
Open No No
RADIUS
UDP/1812,18
13
Open (when config-
ured)
Closed No No
TFTP
UDP/69 Open (when config-
ured)
Closed No No
RIP
UDP/520 Open (when config-
ured)
Closed No No

Table of Contents